2IML-468M Mud Logging Cabin Positive Pressure & Explosion Proof
- Certification standards: DNV2.7-1, DNV2.7-2 ;
- Size: 8m*2.75m*2.8m;8m*2.5m*2.8m;6m*2.5m*2.8m;4.7m*2.5m*2.8m;
- Fire-protection rating: A-0 A-60
- Input voltage: 3P 3W 220/380/440/480 V or Customed
- Maximum power: 30KVA
- Positive pressure ventilation time T1:> 10Min (0 ~ 30Min adjustable)
- Low voltage delay cut off power supply T2:> 30S (0 ~ 10Min adjustable)
- Outlet automatic shut off temperature: 70 ± 2 ℃
- Combustible gas secondary alarm: ≥ 20% LEL
- Combustible gas first level alarm (cut off power): ≥ 50% LEL
- Toxic gas secondary alarm: ≥ 10ppm
- Toxic gas first level alarm (cut off power): ≥ 20ppm
- Cut off power Temperature: ≥ 60 ℃
- Internal pressure with positive pressure status : 60 ~ 120Pa